ANSI C63.19 HAC Workshop with
DASY5 Air at PCTEST Engineering Lab,
Columbia, MD, USA
At the ANSI C63.19 Workshop on Hearing Aid Compatibility Measurements, held on 10 October 2008, training and demonstration of HAC compliance testing was performed on a newly installed DASY5 AIR system at PCTEST Engineering Lab in Columbia, MD, USA.
One of the advantages of the new system is that the wireless device can be tested in the same configuration for RF E-field and RF H-field emissions as well as for T-Coil signals by simply changing the probes. Unlike other sensors, the SPEAG AM1D probe for the audio magnetic (T-Coil) fields incorporates a preamplifier and is fully immune to RF emissions from the wireless device. There is no need to replace the antenna with a coaxial cable, apply shielding or modify the wireless device for the T-Coil test. All orientations are measured with the same probe. The pre-installed signals allow fast scanning (only 1s per point with a voice signal and even faster rates with a sine signal). Also, user defined or standard signals such as the P.50 can be applied.
Some of our customers were not aware that SPEAG performs the filtering for the ABM1 and ABM2 in the time domain, and not the frequency domain, by convoluting the digital data stream with the filter parameters. Therefore, the data provided are fully compliant with the requirements of the standard. The visualization of the third-octave filtered values was conducted independently. To avoid future problems, the third-octave filtered values up to 10 kHz will be displayed in our next release.
The validation devices are now available with ISO 17025 traceable calibration for both the RF and T-Coil parts. New bands have also been added to our broadband RF dipoles for free space that have a high return loss over a wide band and do not require compensation of the reflected power. In addition, the SPEAG TMFS telephone magnetic field simulator with an extremely flat frequency response is available with numerical target values.
Please contact info@speag.com for more product information.
- automated testing of all or selected channels
- automated switching between bands
- automated power stepping
New Phantom - TwinSAM-Chin20
The growing number of mobile phones with antennas at the bottom of the device prompted the FCC to question the appropriateness of the current Twin SAM phantoms if peak absorption occurs in the upper part of the chin. In response, the latest draft of the IEEE1528 revision suggests alternative phantoms enabling accurate measurements for these exposure conditions, i.e., a probe angle of less than 20 degrees with respect to the normal surface.
Once more, SPEAG is the first company to offer a solution satisfying this new requirement.
Please contact info@speag.com for more product information and pricing.
New DASY4 and DASY5 Software Release
Based on our customers valuable feedback, we are pleased to announce a new release of the DASY4 and DASY5 software, namely:
DASY4 V4.7 B71 and SEMCAD V1.8 B184
DASY5 V5.0 B119 and SEMCAD-X V13.2 B 87
HAC RF & T-coil
- updates to the latest standard versions ANSI C63.19-2006 and ANSI C63.19-2007
- visualization of the frequency response mask corrected to 300 - 3000 kHz
- program feedback for compliant distance setting
- increased measurement accuracy by compensating the effect of the dielectric material of the Test Arch on the electric field at close distances
- new HAC Arch phantom model for easier definition of measurement settings
- updated predefined files
- updated predefined files and listing/setting for communication systems
- DASY4 measurement software updated with some minor fixes without influence on the measurement.
- the bug of the CS8 robot series leading to singularity problems in some rare instants could be eliminated by enhanced robot movement predictions in the DASY software. The speed settings for the single movement segments was further accelerated. Joint limits for the NEO systems have been relaxed providing more flexibility during measurements.
- updates to the latest standard versions ANSI C63.19-2006 and ANSI C63.19-2007
- visualization of the frequency response mask corrected to 300 - 3000 kHz
- program feedback for compliant distance setting
- increased measurement accuracy by compensating the effect of the dielectric material of the Test Arch on the electric field at close distances
- new HAC Arch phantom model for easier definition of measurement settings
- updated predefined files
- after successful completion of a research project, SPEAG is proud to announce a new probe type. Vector probes are the most accurate and the only truly universal probes, i.e., vector probes are the only probes that measure without additional isotropic errors in different media if sensitivity/ConvF, sensor angles and boundary compensation parameters are calibrated for the corresponding medium. Furthermore, vector probes provide much useful additional information: E- and H-field polarization of the near-field and far-field; information about amplitude and directions of RF currents inside devices; information about the cause of parasitic coupling, i.e., what couples from where to what.
SAR
- updated predefined files and listing/setting for communication systems
- introduction of new licensing scheme (SAR, AIR, PRO and NEO license levels)
- instant report for all procedures or single jobs within a measurement file automatically printed by right-click
- several software restrictions and bugs have been removed
SHO V2 Hand Phantoms and Accessories

SPEAG is pleased to announce the update of our SHO V2 hand phantoms to provide greater functionality and capability. New accessories are also now available for OTA testing of the hand phantom, promoting accurate, repeatable, and uniform testing of wireless devices.
SHO V2RB/LB
The improved SHO V2RB and SHO V2LB (right and left hand phantoms) provide accurate testing of brick-shaped or candy-bar mobile phones. Superior spacer and measurement tools are included to enable precise and repeatable positioning of the device in the hand.
SHO V2RC/LC
The improved SHO V2RC and SHO V2LC (right and left hand phantoms) provide accurate testing of clam-shell phones. Superior spacer and measurement tools* are included to enable precise and repeatable positioning of the device in the hand.
*Please note that the tools for SHO V2RC/V2LC are not compatible with SHO V2RB/LB. SHO V2RC/LC hands will be available in July 2008.
SAM MASK6/15
SAM MASK6/MASK15 are made from low-loss, low-permittivity material (ROHACELL), providing a 6-degree and 15-degree rotation of the cheeks (as requested by some of the current OTA drafts) respectively. This range of flexibility greatly facilitates the positioning of the phone in the hand at the head.
Please contact info@speag.com for more product information and pricing.
SHO V2 Hand Phantoms and Accessories

SPEAG is pleased to announce the update of our SHO V2 hand phantoms to provide greater functionality and capability. New accessories are also now available for OTA testing of the hand phantom, promoting accurate, repeatable, and uniform testing of wireless devices.
SHO V2RB/LB
The improved SHO V2RB and SHO V2LB (right and left hand phantoms) provide accurate testing of brick-shaped or candy-bar mobile phones. Superior spacer and measurement tools are included to enable precise and repeatable positioning of the device in the hand.
SHO V2RC/LC
The improved SHO V2RC and SHO V2LC (right and left hand phantoms) provide accurate testing of clam-shell phones. Superior spacer and measurement tools* are included to enable precise and repeatable positioning of the device in the hand.
*Please note that the tools for SHO V2RC/V2LC are not compatible with SHO V2RB/LB. SHO V2RC/LC hands will be available in July 2008.
SAM MASK6/15
SAM MASK6/MASK15 are made from low-loss, low-permittivity material (ROHACELL), providing a 6-degree and 15-degree rotation of the cheeks (as requested by some of the current OTA drafts) respectively. This range of flexibility greatly facilitates the positioning of the phone in the hand at the head.
Please contact info@speag.com for more product information and pricing.
New Light-Weight Solid SAM - SAM V4.5BS

Although identical in shape and shell thickness to the SAM Head V4.5CTIA, the new SAM V4.5BS head phantom is filled with a solid material that meets the dielectric specifications of head tissue from 300 MHz – 6 GHz. The new head phantom offers several advantages:
- 30% lighter than phantoms filled with a liquid sugar water solution
- the dielectric parameters are compatible with those defined for the head simulating liquid of the IEEE/IEC standards from 300 MHz – 6 GHz
- the solid material does not separate
- the solid material does not leak, even if the very robust head is accidentally damaged (e.g., by dropping it on the floor).
The head is compatible with our device holders and hand fixtures/positioner. Please contact info@speag.com for more product information and pricing.
New Light-Weight Solid SAM - SAM V4.5BS

Although identical in shape and shell thickness to the SAM Head V4.5CTIA, the new SAM V4.5BS head phantom is filled with a solid material that meets the dielectric specifications of head tissue from 300 MHz – 6 GHz. The new head phantom offers several advantages:
- 30% lighter than phantoms filled with a liquid sugar water solution
- the dielectric parameters are compatible with those defined for the head simulating liquid of the IEEE/IEC standards from 300 MHz – 6 GHz
- the solid material does not separate
- the solid material does not leak, even if the very robust head is accidentally damaged (e.g., by dropping it on the floor).
The head is compatible with our device holders and hand fixtures/positioner. Please contact info@speag.com for more product information and pricing.
New DASY4 and DASY5 Software Release
Based on our customers' valuable feedback, we are pleased to announce new releases of the DASY4 and DASY5 software, namely:
DASY4 V4.7 B71 and SEMCAD V1.8 B184
DASY5 V5.0 B119 and SEMCAD-X V13.2 B 87
The new DASY releases provide new features in the following areas:
Robot Movements (DASY5 only)
- The bug of the CS8 robot series leading to singularity problems in some rare instants could be eliminated by enhanced robot movement predictions in the DASY software. The speed settings for the single movement segments was further accelerated. Joint limits for the NEO systems have been relaxed providing more flexibility during measurements.
HAC RF & T-coil- updates to the latest standard versions ANSI C63.19-2006 and ANSI C63.19-2007
- visualization of the frequency response mask corrected to 300 - 3000 kHz
- program feedback for compliant distance setting
- increased measurement accuracy by compensating the effect of the dielectric material of the Test Arch on the electric field at close distances
- new HAC Arch phantom model for easier definition of measurement settings
- updated predefined files
SAR- updated predefined files and listing/setting for communication systems
Universal (Pseudo-Vector) Probes (DASY5 only)
- After successful completion of a research project, SPEAG is proud to announce a new probe type. Vector probes are the most accurate and the only truly universal probes, i.e., vector probes are the only probes that measure without additional isotropic errors in different media if sensitivity/ConvF, sensor angles and boundary compensation parameters are calibrated for the corresponding medium. Furthermore, vector probes provide much useful additional information: E- and H-field polarization of the near-field and far-field; information about amplitude and directions of RF currents inside devices; information about the cause of parasitic coupling, i.e., what couples from where to what.
In summary, vector probes are universal probes and a great analysis tool. They should be used wherever great precision is needed, field polarization must be validated or parasitic currents detected. The measurement time compared to isotropic probes is only increased by just more than a factor two (minimally three measurements at different angles need to be taken at each measurement point).
General- introduction of new licensing scheme (SAR, AIR, PRO and NEO license levels) (DASY5 only)
- instant report for all procedures or single jobs within a measurement file automatically printed by right-click (DASY5 only)
- several software restrictions and bugs have been removed (DASY5 only)
- DASY4 measurement software updated with some minor fixes without influence on the measurement
New DASY4 and DASY5 Software Release
Based on our customers' valuable feedback, we are pleased to announce new releases of the DASY4 and DASY5 software, namely:
DASY4 V4.7 B71 and SEMCAD V1.8 B184
DASY5 V5.0 B119 and SEMCAD-X V13.2 B 87
Robot Movements (DASY5 only)
- The bug of the CS8 robot series leading to singularity problems in some rare instants could be eliminated by enhanced robot movement predictions in the DASY software. The speed settings for the single movement segments was further accelerated. Joint limits for the NEO systems have been relaxed providing more flexibility during measurements.
HAC RF & T-coil- The bug of the CS8 robot series leading to singularity problems in some rare instants could be eliminated by enhanced robot movement predictions in the DASY software. The speed settings for the single movement segments was further accelerated. Joint limits for the NEO systems have been relaxed providing more flexibility during measurements.
- updates to the latest standard versions ANSI C63.19-2006 and ANSI C63.19-2007
- visualization of the frequency response mask corrected to 300 - 3000 kHz
- program feedback for compliant distance setting
- increased measurement accuracy by compensating the effect of the dielectric material of the Test Arch on the electric field at close distances
- new HAC Arch phantom model for easier definition of measurement settings
- updated predefined files
- updated predefined files and listing/setting for communication systems
- After successful completion of a research project, SPEAG is proud to announce a new probe type. Vector probes are the most accurate and the only truly universal probes, i.e., vector probes are the only probes that measure without additional isotropic errors in different media if sensitivity/ConvF, sensor angles and boundary compensation parameters are calibrated for the corresponding medium. Furthermore, vector probes provide much useful additional information: E- and H-field polarization of the near-field and far-field; information about amplitude and directions of RF currents inside devices; information about the cause of parasitic coupling, i.e., what couples from where to what.
- introduction of new licensing scheme (SAR, AIR, PRO and NEO license levels) (DASY5 only)
- instant report for all procedures or single jobs within a measurement file automatically printed by right-click (DASY5 only)
- several software restrictions and bugs have been removed (DASY5 only)
- DASY4 measurement software updated with some minor fixes without influence on the measurement
TMFS (Telephone Magnetic Field Simulator)
In response to several requests, we have developed the Telephone Magnetic Field Simulator (TMFS), designed according to ANSI S3.22-2003.
A TMFS unit is intended to use as a reference check of the test setup and instrumentation prior T-Coil signal measurements.
The SPEAG TMFS has been optimized for an easy positioning/usage with the already available HAC Test Arch . The signal to 600 Ohm input can be supplied either from a separate, calibrated source or from the AMMI unit. A second connector allows monitoring the signal with a calibrated voltmeter. The TMFS has a flat frequency response and includes calibration at 1kHz for the axial and radial field maxima at 10mm scanning distance.
Please contact info@speag.com for more information and quotes.SHO V2 (SAM HAND OTA Version 2)
SPEAG is pleased to announce the long awaited hand phantoms (SHO V2) for our SAM V4.5 head phantoms, which may be used as part of a system to conduct testing to CTIA's Test Plan for Mobile Station Over the Air Performance. Since accurate positioning of the phone in the hand and at the head is a key parameter to obtain results with low uncertainty, we have integrated a high precision fixture/positioner that provides minimal uncertainty and is easy-to-use. Get the best solution on the market before the standard is even issued! SPEAG also provides adapters for the SAM V4.5 with SHO V2 for most OTA systems. Please contact info@speag.com for more information and quotes for right and left hands (SHO V2R and SHO V2L) and for their fixture/positioner.
SAM V.4.5 Adapters for ETS OTA System Now Available
SPEAG is committed to providing adapters for all OTA systems, since many users have expressed the wish to use the high precision SAM V4.5 with their systems. As the first step toward achieving this goal, we can now provide SAM V4.5 adapters for the ETS systems.New DASY4 and DASY5 Software Release
Based on our customers valuable feedback, we are pleased to announce a new release of the DASY4 and DASY5 software, namely:
DASY4 V4.7 Build 55 and SEMCAD V1.8 Build 176
DASY5 V5.0 Build 87 and SEMCAD X V12.4 Build 52
The new DASY4 release provides the upgrade of the HAC features for compatibility with the latest version: ANSI C63.19-2007. The changes include:
HAC RF- Postprocessor incorporates limits from ANSI C63.19-2007 for M-classes.
- Sophisticated interactive handling of combined HAC RF evaluations.
- Probe Modulation factor can be modified during visualization of the HAC RF subgrids.
- HAC RF exclusion subgrids can be modified on-line with immediate visualization of the effect on the combined class. These settings are also used in the combined field report.
- Predefined measurement files have been updated for compliance with the new measurement distance of 15mm for devices.
- PMF determination is supported by detailed instruction, predefined files and evaluation sheet.
HAC T-Coil
- Postprocessor incorporates limits from ANSI C63.19-2007 for T-classes.
- Reporting includes more detailed information on signal type, amplitude setting etc.
- Procedure to determine correct audio level setting for R&S CMU200.
- Next generation of sample file for T-Coil setup and measurements as a basis for customer specific modifications.
General
- DASY4 measurement software updated with some minor fixes without influence on the measurement.
Download the NEW DASY4 Software!
The new DASY4 software upgrade is now available for download from the DASY
homepage www.speag.com/measurement/support/dasy4/index.php
The new DASY5 release provides new features in the following areas:
SAR
Implementation of SAR correction for deviations of permittivity and conductivity according to the latest drafts of IEEE 1528 and IEC 62209-2 standards. The target liquid parameters are included in the Inventory->Medium folder as *.txt files. This feature can be enabled or disabled by activating the check box "Use target values for SAR correction".
Fast SAR algorithm extended to frequencies up to 6 GHz according to paper "Accurate and Fast Estimation of Volumetric SAR from Planar Scans from 30 MHz to 6 GHz" by M. Douglas, CK Chou, BEMS Abstract book 2007, page 189-191.
HAC
Upgrade of the HAC features for compatibility with the latest version: ANSI C63.19-2007 including:
HAC RF
- Postprocessor incorporates limits from ANSI C63.19-2007 for M-classes.
- Sophisticated interactive handling of combined HAC RF evaluations.
- Probe Modulation factor can be modified during visualization of the HAC RF subgrids.
- HAC RF exclusion subgrids can be modified on-line with immediate visualization of the effect on the combined class. These settings are also used in the combined field report.
- Predefined measurement files have been updated for compliance with the new measurement distance of 15mm for devices.
- PMF determination is supported by detailed instruction, predefined files and evaluation sheet.
HAC T-Coil
- Postprocessor incorporates limits from ANSI C63.19-2007 for T-classes.
- Reporting includes more detailed information on signal type, amplitude setting etc.
- Procedure to determine correct audio level setting for R&S CMU200.
- Next generation of sample file for T-Coil setup and measurements as a basis for customer specific modifications. A high speed version allows scanning one configuration completely within 35 minutes.
General
- Several software restrictions and bugs have been removed.
The new DASY5 software upgrade is now available for download from the DASY homepage www.speag.com/measurement/support/dasy5/index.php
Travel Case / Car Torso (TCCT)
In response to several requests, we have developed the Travel Case / Car Torso (TCCT). The TCCT combines two functionalities. It provides the means to safely transport the SAM Head V4.5 and V4.5CTIA but also to securely mount the SAM Head on a car seat to test communication performance under actual network conditions. Please contact info@speag.com for more information and quotes.
Precise Field, SAR and T Measurements
in MRI
EASY4MRI makes its worldwide debut as the first ever line of measurement equipment that is fully compatible for operation within MRI scanners (tested in 1.5T and 3T, 7T to be tested next month). It enables measurement of the incident H-field (B1-field) and E-field (E1-Field) with a precision of better than 6% and an isotropy error of better than +/- 0.3dB (link to both probes). All three components can be evaluated separately. The induced fields or SAR values in body simulating phantoms (e.g., ASTM) can be measured with a precision of better than 12% using the world's smallest isotropic dosimetric probe EX3DV4. The system is also compatible with the most sensitive temperature probes (noise level <2 mK) available today. All probes can be accurately positioned using the modified ASTM phantom.
Facedown Head Phantom SAM 6.0

In response to several requests, we have developed the facedown phantom SAM V 6.0 . It allows assessment of the exposure of the face and in particular the eyes for handheld devices operated in front of the face, e.g., video phones, cameras, organizers, etc. The facedown head phantom is manufactured using high precision injection molding (shell thickness except for the ear: 2 +/- 0.2mm) and is compatible with all of our tissue simulating liquids. The same device positioner (Mounting Device including extension kit) can be used to position the device. A special software extension allows accurate measurements within the region of the eyes and nose. Please contact info@speag.com for more information and quotes.
DASY5 – Released

The next generation of near-field scanners, the DASY5 systems, was released in January 2007 and on February 14, the first DASY5 PRO has been installed at Telecom Italia Lab in Turin. Please find background information, a summary of the features as well as upgrade information for DASY3 and DASY4 systems in the DASY5 Release Note of March 07 (PDF, 95 kB).
Please contact info@speag.com for more information and quotes.
Laptop Extensions Kit for Mounting Devices
SPEAG has developed a simple but effective and easy-to-use extension for our Mounting Device that facilitates the testing of larger devices according to IEC 62209-2 (e.g., laptops, cameras, etc). The extension is lightweight and made of POMM, acrylic glass and foam. It fits easily on the upper part of the Mounting Device in place of the phone positioner. The extension is fully compatible with the Twin-AM and ELI4 phantoms. Please contact info@speag.com for more information and quotes. ![]() | ![]() |
Phone Numbers: Change in Area Code
As per April 1, 2007 our local area code will change from 1 to 44. Please note our new main phone and fax number:| Phone | +41 44 245 9700 (old: +41 1 245 9700) |
| Fax | +41 44 245 9779 (old: +41 1 245 9779) |
For direct phone numbers of our staff please refer to the signatures in any e-mail correspondence.
Release of iSAR v1.1
iSAR V1.1, the latest software update for iSAR, delivers new performance features designed to significantly reduce measurement uncertainty and increase repeatability to an unprecedented <+/-2%. Release V1.1 adds the functionality of Combiner, a high-end intelligent data post-processor that combines various measurements (< 10 measurements @ 3 sec/measurement) to further increase the spatial resolution and eliminate uncertainties, such as interpolation, sensor isotropy and sensor-to-sensor calibration variations, etc.In addition, as a new service, we provide calibrations for a wide variety of wireless systems as well as customer specific calibrations.
iSAR is the highest-performing R&D, pre-compliance and QA testing device available.
![]() | |
First iSAR V1 Installed at BenQ Mobile, Munich

SAM Head Phantom V4.5CTIA is approved by the CTIA Certification Standard

SPEAG is pleased to announce that our new SAM phantom SAM V4.5CTIA is fully compatible with the CTIA Certification Standard "Test Plan for Mobile Station Over the Air Performance" Revision 2.2 as well as the 3GPP TR25.914 "Measurements of Radio Performances for UMTS Terminals in Speech Mode" Release 6. A detailed analysis conducted by the IT’IS Foundation, Zurich, demonstrated that specific features of this phantom provide a smaller uncertainty and greater repeatability. These features include:
- high precision injection molding of the phantom head
- a means for very robust mounting
- a phone positioner allowing precise and repeatable positioning of the phone.
In addition, the redesigned transparent cap allows for the detection and elimination of enclosed air bubbles.
SAM V4.5 is still available but only compatible with 3GPP.
SPEAG is Committed to Producing Environmentally Friendly Products (RoHS Directive)
SPEAG is committed to maintaining compatibility with the new RoHS directive, even though it is not mandatory for our specific products. The RoHS Directive specifies "restriction of the use of certain hazardous substances in electrical and electronic equipment" and will prohibit placement on the EU market of new electrical and electronic equipment containing more than the agreed levels of lead, cadmium, mercury and other hazardeous substances as of July 1st, 2006. Other countries worldwide have drafted or are intending to introduce similar restrictions to protect our environment from avoidable pollution. The focus is specifically on hazardous substances in widespread consumer products.
We have undertaken the following measures for our products:
- assessment of hazardous substances in our products
- application of RoHS requirements and declarations for parts produced/delivered from our vendors
- introduction of lead-free soldering
- use of lead-free components whenever available
- elimination of cadmium-based batteries
- reduction of harmful substances in our products and packing materials whenever possible
While remaining at the forefront of current regulations, we are also continuing our tradition of environmentally friendly commitment.
New Transparent Cap Makes SAM Head V4.5 CTIA Compatible

The transparent cap is manufactured of PMMA and has very long-lasting resistance to all current tissue simulating liquids except DGBE recipes. This cap has been designed to meet the CTIA guidelines “Test Plan for Mobile Station over the Air Performance, April 2005”. In compliance with these rules, incidentally enclosed air can be detected and eliminated easily. All SAM Heads V4.5 will be delivered with the new cap. For upgrades, or for DGBE compatible solutions, please contact us at info@speag.com.
Release of ABM Extension for DASY4

We proudly announce the release of a further new product: the Audio Band Magnetic (ABM) Extension for DASY4. This product complements our HAC RF Extension and enables all of the measurements required by ANSI-PC63.19 for Hearing Aid Compatibility to be conducted using DASY4. The extension includes:
- Active Audio Magnetic Field Probe (AM1DV2)
- Helmholtz Calibration Coil (AMCC)
- Audio Magnetic Measurement Instrument (AMMI)
- Software HAC V4.7
The new Software HAC V4.7 integrates the new ABM measurements into DASY4. Calibration and test signals are controlled by the PC. The audio signals, collected via the audio output of the AMMI from a base station simulator to wireless device connection, are scanned in axial and radial directions with the probe, sampled by the AMMI and evaluated in the DASY4 PC. Spectral processing and evaluation is in accordance with the requirements of ANSI-PC63.19 for ABM1, ABM2, spectral response, signal level, etc.
SCS108: Extended Scope of Calibration
SPEAG is pleased to announce that the scope of the calibration services of our SCS108 accredited calibration laboratory has been extended to (valid as of
October 1, 2005):
- Calibration of dosimetric probes (EX3DVx type) in the frequency range
3 - 6 GHz - Calibration of system validation dipoles in the frequency range 3 - 6 GHz
- Calibration in air of HAC dipoles
As with the the previous scope, the frequency validity of a ConvF is extended to ± 100 MHz for DASY V4.4 and higher.
Call for Participation in Round-Robin Test
for DASY4 Customers
The general concept of the envisioned round-robin SAR testing is to use two mobile phones (DUT) having typical SAR distributions together with the SAM-Twin phantom filled with the head-tissue simulating liquid, whereby the two phones and the liquid would be supplied by SPEAG. Each laboratory would follow a measurement protocol defined and described in detail by SPEAG.
The number of different SAR assessments (e.g. frequencies and DUT positions) will be chosen such that the measurement time does not exceed 1 working day per laboratory. Participation fee and the duration of the round-robin exercise will strongly depend on the number of interested laboratories and will be announced later.
If you would be interested to participate, please send an e-mail to support@speag.com
Release of Major DASY4 Software
Upgrade V4.5
We are pleased to announce the release of our DASY4 software version V4.5 including the DASY4 Application as well as the SEMCAD Postprocessor. This major upgrade is free of charge for all DASY4 customers. In addition of the many new enhancements, Version 4.5 features a new software package (licensed) for compliance tests according to ANSI-C63.19-2001. This latter requires the recently introduced hardware "Hearing Aid Extension for the DASY4 systems". A summary of the new features and functions included in V4.5 are:
- Software support for newly released HAC extension for DASY systems (licensed)
- Interpolation of measured data for all 2D and 3D Scans
- Maximum measured values indicated in DASY
- Enhanced and fully automated noise suppression algorithm
- Date/Time on the printout corresponds to the actual measurement Date/Time
- Surface Check job has now two modes (the second mode used during HAC measurements)
- Simple box phantom can be taught now using one- or three- reference points teaching principle
- Added new jobs under Robot Command
- Implemented "Re-Evaluate" function in DASY4
- Provision of additional information via the SEMCAD printout facility (general, HAC related, etc.)
- Updated DASY4 User Manual including new and updated Application Notes
The new DASY4 V4.5 software upgrade is now available for download from the DASY4 homepage via www.dasy4.com/updates/updates.html.

ELI4
Phantom for compliance testing of handheld and body-mounted wireless devices in the frequency range of 30 MHz to 6 GHz. ELI4 is fully compatible with the latest draft of the standard IEC 62209 Part II and all known tissue simulating liquids. ELI4 has been optimized regarding its performance and can be integrated into our standard phantom tables. Filling volume about 30 liters. The phantom will become available by March 2005.
Further details available at www.dasy4.com or support@speag.com.